Exposure control plan

An exposure control plan translates a hazard standard into assigned work: the covered tasks and employees, the controls for those tasks, and the records showing implementation. Its contents depend on the rule. A construction silica task sheet does not supply the bloodborne-pathogen exposure determination or incident-review procedure. Name the governing standard on the plan cover and organize the working instructions around actual operations.

The required written document describing the tasks, controls, housekeeping, and restricted access for the job

Used across 2 Anvilfield field guides, most in Concrete.
Updated

Start with the rule that creates the duty

OSHA 1926.1153(a) excludes construction silica exposures only when they remain below 25 µg/m³ as an eight-hour TWA under any foreseeable conditions. A favorable reading from one quiet shift does not, by itself, establish that scope exclusion for cutting, cleanup and foreseeable changes in production.

For a covered construction operation, use the four elements in OSHA 1926.1153(g)(1) as a check on the working task sheet. The entries below show what makes each element traceable to a crew's work; the silica program guide connects the sheet to the wider program.

Required silica-plan elementTask-sheet detail
Exposure-generating tasksIdentify the slab cut, work location, material and saw.
Controls, work practices and respiratory protection for each taskIdentify the approved saw-control combination and the applicable respirator decision.
HousekeepingName the slurry or collected-dust removal method for this operation.
Access restrictions where necessaryIdentify affected adjacent crews and how the work boundary will be maintained.

Determine bloodborne exposure before crediting PPE

For bloodborne pathogens, OSHA 1910.1030(c)(2)(ii) puts the exposure determination before any credit for gloves or face protection. List the exposed job classifications and, where only some employees in a classification are exposed, the specific exposure-generating duties. A driver's transport-only assignment and the same driver's added spill-response assignment need different entries.

A cleanup company assigns six technicians to contaminated-material removal and two drivers to transport duties. Describe the technicians' assigned work and determine whether either driver's actual duties involve reasonably anticipated blood or other potentially infectious material contact. Do not average exposure across eight employees or exclude the removal team because protective clothing is worn. The biohazard cleanup guide covers the resulting protection program.

OSHA 1910.1030(c)(1)(ii) also requires the implementation schedule and method for applicable compliance, vaccination, follow-up, communication and recordkeeping duties, plus a procedure for evaluating exposure-incident circumstances. Assign responsible roles and document locations beside those duties. A PPE list by itself leaves these required parts unanswered.

Update for changed duties, not just the anniversary

Both OSHA 1926.1153(g)(2) and 1910.1030(c)(1)(iv) set an annual review duty, but the bloodborne rule also expressly requires revisions for changed exposure-related tasks or positions. Its review includes technology changes and an annual record of consideration and implementation of appropriate safer medical devices. Adding spill response to a driver's duties cannot wait for the anniversary.

For construction silica, the designated competent person implements the plan through frequent and regular inspections under 1926.1153(g)(4). That assignment belongs to the silica rule; it is not a universal job title imposed on every document called an exposure control plan.

Use a dated revision record identifying the changed operation, affected employees and replacement instructions. Attach the completed review to the relevant hazard program, retire superseded task sheets and keep the current plan accessible. The bloodborne rule's review record and the silica competent person's field inspections establish different parts of implementation.

Distinctions

Job hazard analysis
Breaks a job into steps and hazards. It supplies useful task detail, but its title does not establish that the hazard standard's required exposure-plan elements are present.
Exposure measurement record
Documents an assessment result and its conditions. The control plan assigns how the employer manages the covered work; the two records serve different purposes.

Frequently asked questions

Can one company document cover silica and bloodborne pathogens?

Yes, provided the applicable requirements remain identifiable. Separate the coverage decisions, task assignments and implementation provisions so a silica control sheet is not mistaken for the bloodborne-pathogen program.

Sources checked

Also defined as

  • Plumbing: The written plan OSHA 1910.1030 requires, naming exposures, controls, training, the Hep B offer, and the post-exposure response