ANVILFIELD Try FieldOS

Field glossary · measurement

Retroreflectivity

For pavement markings, retroreflectivity is reported as RL in mcd/m²/lx, the light returned toward the headlight source under a stated viewing geometry. A portable retroreflectometer measures that response; white-looking paint in daylight does not. MUTCD maintenance levels concern dry longitudinal road markings under defined speed and scope conditions. They do not establish wet-night performance or replace a new-material acceptance specification.

Light from a headlight returned toward the driver by glass beads, measured in mcd/m2/lux at 30-meter geometry

Used across 2 Anvilfield field guides, most in Paving.
Updated

Read the speed threshold and the paragraph type together

MUTCD section 3A.05 requires a method designed to maintain longitudinal markings at or above 50 mcd/m²/lx in dry conditions on roadways with speed limits of at least 35 mph, subject to its listed exclusions. The requirement is for a maintenance method, not necessarily a meter reading of every marking.

MUTCD section 3A.05 recommends at least 100 mcd/m²/lx dry for longitudinal markings where the speed limit is 70 mph or higher. That is Guidance, distinct from the mandatory maintenance-method provision at 50 mcd/m²/lx. The September 6, 2026 deadline in Table 1B-1 has passed as of this review; the method for covered markings must already be implemented and continuing in use.

Check whether the marking belongs in that requirement

MUTCD section 3A.05 permits exclusion of markings with adequate ambient illumination, on roads below 6,000 ADT, and on shared-use paths, as well as dotted intersection extensions, curb markings and parking-space markings. Transverse markings, words, arrows, crosswalks and chevron or crosshatch markings fall outside these longitudinal-marking maintenance provisions.

Document the marking type and any exclusion being used. A crosswalk or parking stall can still have project-specific visibility and material requirements, but transferring the longitudinal-roadway threshold without checking scope misstates what the federal provision says. The MUTCD entry explains the facility boundary as well as the paragraph categories.

Compare readings made at the same optical geometry

ASTM E1710-18(2025) specifies entrance and observation angles of 88.76 degrees and 1.05 degrees for portable measurement of bead-based pavement markings. Its geometry represents a 30-meter viewing distance, a 0.65-meter headlight height and a 1.2-meter eye height.

Log the instrument geometry, direction of travel, location and surface condition beside each RL value. Compare readings made under the same conditions; a dry value does not describe a water film’s effect or establish a wet-recovery result.

Quantity on the meter recordReporting unit
Coefficient of retroreflected luminance, RLmcd/m²/lx (millicandelas per square meter per lux)

Distinctions

Reflectance
A surface can reflect substantial light in other directions without returning enough toward the source to make a good nighttime marking.
Initial acceptance
An installation acceptance limit evaluates new material under stated test conditions. A maintained minimum supports the agency’s continuing inspection and renewal program.

Frequently asked questions

Does one high reading establish the condition of a whole route?

It establishes the sampled location under the recorded conditions. Route decisions need the sampling or assessment method used by the maintaining agency, including treatment of wear, variation and excluded markings.

Sources checked

Also defined as

  • A marking's ability to bounce headlight beams back to the driver, the measure of night visibility

Where this shows up

Next step: See marking contracts

Back to the full field glossary