Plumbing
No hot water from a tankless heater? Navien, Rheem and A. O. Smith checks
Exact-model checks for activation flow, fault codes, cold-water sandwich and distribution problems, with a worked flow comparison and a service handoff record.
Direct answer
Check power and the controller's enabled state, record the exact model and fault code, then compare one fixture with the rest of the building. The published minimum through-heater flows are 0.5 GPM for Navien NPE-180S2 in its January 2026 Installation Manual, 0.4 GPM activation for Rheem IKONIC RTGH-S11i in AP23209 Rev 03, and 0.5 GPM startup at the default temperature for A. O. Smith ATI-540H in 2000534710 Rev. C. When confirmed flow is sufficient but water stays cold, match the heating state and literal code to that model's manual; when the heater outlet is hot but one fixture stays cold, follow the mixing and distribution branch. For gas odor, leave and call the gas supplier from outside; for a carbon monoxide alarm, leave and call emergency services.
On this page
Which model and manual apply?When do you stop checking and leave?Is the fault at the fixture, heater or supply?What flow starts each heater?How do you measure flow and separate it from mixing?Which Navien codes apply to NPE-2?Which Rheem codes apply to IKONIC?Which A. O. Smith codes apply to ATI-540H?Is it a cold-water sandwich, crossover or recirculation fault?Why do winter weather and large draws change the answer?When do maintenance and resets belong in diagnosis?What should the service quote include?What should you record before handing the job over?Open the related tool for the calculation, checklist, or packet.
FieldOS by AnvilfieldOffline-first FieldOS for job photos, proof packets, property memory, calculations, teams, billing, and owner-ready reports.Which model and manual apply?
Start with the rating plate, not the brand name on the cabinet. Photograph the full model, series, serial number, fuel and conversion label, then identify the indoor or outdoor arrangement, controller and any linked heaters. Preserve model suffixes when selecting instructions; a conversion label is relevant only where that manufacturer permits conversion.
This comparison covers gas condensing Navien NPE-180S2, Rheem IKONIC RTGH-S11i and RTGH-SR11i, and A. O. Smith ATI-540H-N, Series 100. Navien NPE-180A2 appears separately because its internal pump, buffer and recirculation configuration change low-flow delivery. Electric tankless heaters, combi boilers and other generations need their own manuals.
A. O. Smith's ATI-540H Series 100 support listing marks that model discontinued and links the operating manual used here.
What belongs in the manual register?
Record the document title, identifier, revision, printed page and direct URL alongside the asset. Navien's download listing calls its installation document an installation and operation manual, while the served PDF is titled Installation Manual, Version 2.0, January 2026, 20049624B; the separate user's manual is Version 1.0, 2020, 20049624A.
The installation manual governs installation and supply limits, the user's manual supports normal observations, and the technical manual supplies service diagnostic paths. For selection rather than fault diagnosis, compare water heater types.
| Model scope | Application | Governing documents | Edition / identifier | Relevant location | Applicability rule |
|---|---|---|---|---|---|
| Navien NPE-180S2 | Gas condensing; S2 configuration | Installation Manual, S2; User's Information Manual, S3 | S2: Version 2.0, January 2026, 20049624B; user: Version 1.0, 2020, 20049624A | Installation specifications p. 7; user troubleshooting pp. 16-18 | The NPE-S2 model does not receive the A2 low-flow recirculation exception |
| Navien NPE-180A2 | Gas condensing with internal pump and buffer | Same family documents, plus specification sheet, S4 | Specification 1-NPE2-SS-001-1.1; family manual as above | Installation p. 27 and specifications p. 7 | Low-flow option requires A2 configuration |
| Rheem IKONIC RTGH-S11i / RTGH-SR11i | Gas condensing; SR has built-in recirculation | Technical Training and Service Manual, S5; Use and Care Manual, S6 | AP23209 Rev 03; AP22745 Rev 04 | Technical p. 7, pp. 37-45, 60, 64; user service chart p. 93 | Preserve prefixes; pump faults remain SR-specific |
| A. O. Smith ATI-540H-N, Series 100 | Indoor gas condensing; discontinued listing | Model support listing, S7; Installation Manual and Owner's Guide, S8; specification, S9 | 2000534710 Rev. C, 68A161-7; AOSRG46835, April 2023 | Owner pp. 46, 50-56, 64; spec p. 2 | Preserve 540, indoor and Easy-Link qualifiers |
When do you stop checking and leave?
Gas odor ends the diagnostic sequence. The front-cover warnings in Navien NPE-2 Installation Manual v2.0, Rheem AP22745 Rev 04 and A. O. Smith 2000534710 Rev. C direct occupants not to attempt ignition, operate electrical switches or use a telephone inside; leave and call the gas supplier from outside, then the fire department if the supplier cannot be reached. Follow the supplier's instructions about reentry.
The U.S. Consumer Product Safety Commission's CO guidance directs occupants to move outside immediately when a carbon monoxide alarm sounds, call emergency services and wait for responder permission before reentering.
A damaged or disconnected vent, soot, flooding, or water contacting electrical equipment also ends firing trials. Navien NPE-2 User's Information Manual v1.0, p. 5, requires discontinued operation for damaged venting; Rheem AP22745 Rev 04, p. 3, prohibits operation without proper venting. Use the model's shutdown instructions only from a safe location; stay clear of wet electrical equipment. The water-heater venting and combustion air guide explains the installation questions a technician must resolve.
A. O. Smith 2000534710 Rev. C, pp. 6 and 31, requires a flooded heater to be replaced by a qualified installer or service agency. Drying it out and resetting it is not the prescribed remedy. Navien's v1.0 user manual, p. 5, instead requires inspection before reuse after flood damage; preserve the installed manufacturer's disposition.
Safe observations are the accessible display, literal code, normal heating indicator, affected fixtures and visible external conditions. Measure discharge temperature with a suitable thermometer, and collect water only where the stream is safe to handle. Gas-pressure measurement, combustion analysis, internal wiring tests, component replacement and vent alteration belong to a qualified service technician; never defeat scald protection to force activation. The temperature warnings in Rheem AP22745 Rev 04, p. 4, and A. O. Smith 2000534710 Rev. C, p. 46, apply during diagnostic draws as well as normal use.
Is the fault at the fixture, heater or supply?
Describe what fails before choosing a test. No water at the hot tap, cold water flowing normally, delayed hot water, a cold interruption and lukewarm water during heavy use are different complaints.
Compare one affected fixture with a second accessible fixture while recording heater flow and heating state. If the second fixture gets hot, the heater has demonstrated heat production under that draw condition. The first fixture still needs its own flow and temperature comparison: a restricted cartridge or mixer can reduce hot-side demand enough to prevent activation.
A. O. Smith's 2000534710 Rev. C says the controller display goes dark after five minutes without operation; Easy-Link child controllers also do not display the set temperature. Check the STAND BY indicator and normal demand response before treating a blank screen as a power failure. Standby power alone does not establish burner operation.
These gas heaters still require electricity for controls and operation. The ATI-540H no-hot-water checklist specifies 120 VAC, 60 Hz, so record a recent outage and whether the controller is enabled before attributing the symptom to a failed board. When both hot and cold flow are weak throughout the building, follow water-pressure and PRV diagnosis alongside the heater checks.
The following triage is Anvilfield's diagnostic interpretation of the manufacturer troubleshooting paths. Note recent plumbing work, accessible shutoff positions and previous resets without operating unfamiliar gas valves.
| Observation | First comparison | Plausible branch | Next action / boundary | Source |
|---|---|---|---|---|
| No hot-side flow | Cold supply; other hot fixtures | Supply closed, obstruction or freezing | Record outlets and freeze exposure; no dry firing | S3 p. 16; S8 p. 52 |
| Dark display; all fixtures cold | Outage; standby; demand response | Sleep, disabled control or power fault | Account for ATI-540H sleep/Easy-Link; then verify power | S8 pp. 52-53 |
| One shower cold; another hot | Heater state during each draw | Local restriction, mixer or cross connection | Compare local flow/temperature; fixture diagnosis | S3 p. 16; S8 p. 52; Anvilfield interpretation |
| Cold flow; no heat/code | Heater flow; enabled state; inlet versus setpoint | Low/unsensed flow or warm inlet | Table 3; confirm state/temperature before sensing diagnosis | S3 p. 16; S5 p. 37; S8 p. 52 |
| Hot-cold-hot after stopping and restarting | Continuous draw versus restart draw | Restart thermal gap | Record timing; check model's buffer/recirculation arrangement | S2 p. 27; S10 |
| Repeated cold during continuous draw | Flow/flame during interruption | Flow dropout, supply interruption or control fault | Log sequence/code; model diagnostics | S3 pp. 16-18; S8 p. 52 |
| Hot outlet but cooler mixed fixture | Outlet/fixture temperatures; draw state | Distribution heat loss or mixing/crossover | Verify mixing/return arrangement | S3 p. 16; S8 p. 52 |
| Multiple fixtures: lukewarm/reduced flow | Inlet temperature; manufacturer capacity curve | Output or fuel limitation | Compare temperature rise and dynamic gas pressure | S5 p. 60; S8 pp. 51-52, 64 |
What flow starts each heater?
Navien's January 2026 NPE-2 Installation Manual lists 0.5 GPM as the NPE-S2 minimum flow, with a separate less-than-0.01 GPM option for A2 models. The A2 option belongs to its documented ComfortFlow recirculation configuration; it is not an S2 ignition adjustment. See the installation specification, p. 7 and the specification footnote before applying it.
Rheem's IKONIC Technical Training and Service Manual AP23209 Rev 03 specifies 0.4 GPM minimum activation flow and 0.26 GPM extinction flow for RTGH-S11i and RTGH-SR11i.
A. O. Smith's ATI-540H Owner's Guide 2000534710 Rev. C requires 0.5 GPM to activate at the default temperature and 0.4 GPM to continue firing after ignition.
Compare those limits with flow through the heater. A shower's mixed discharge contains cold water that never passed through the heater, while other fixtures and recirculation can add heater flow. Startup, continuation, sensor resolution and maximum thermal output describe separate boundaries; a rounded controller reading exactly at a threshold does not prove a stable operating margin.
Why can a second tap make the hot water work?
A second hot-side draw can lift total heater flow above startup. Record the flow and heating response with each fixture alone and with both open; that supports a flow-related branch without identifying the restriction or sensor at fault. For the scoped models, Anvilfield's arithmetic places 0.45 GPM between ATI-540H continuation and startup, and 0.30 GPM between IKONIC extinction and activation.
| Exact scope | Starting/minimum flow | Continuing/extinction flow | Condition / exception | Field interpretation | Source |
|---|---|---|---|---|---|
| Navien NPE-180S2 | 0.5 GPM / 1.9 L/min listed minimum | Separate continuation value not specified | Standard NPE-S2; no A2 option | Compare published minimum with observed heating | S2 p. 7; S3 p. 16 |
| Navien NPE-180A2 | 0.5 GPM family minimum; less than 0.01 GPM / 0.04 L/min option for A2 | Not specified here | Optional ComfortFlow; stored heat/controls; increased energy use | Configured delivery performance; distinct from burner startup | S2 pp. 7, 27; S4; S10 |
| Rheem RTGH-S11i / RTGH-SR11i | 0.4 GPM | 0.26 GPM extinction | AP23209 Rev 03 scope | Compare startup and running complaints separately | S5 p. 7 |
| A. O. Smith ATI-540H-N | 0.5 GPM / 1.9 L/min | 0.4 GPM / 1.5 L/min continuous firing | Activation value at default set temperature | Below startup does not necessarily mean below continuation | S8 p. 46; S9 p. 2 |
How do you measure flow and separate it from mixing?
Divide collected gallons by collection seconds and multiply by 60 to obtain gallons per minute. Use a marked container and a timer, keep the draw steady, and repeat the collection before comparing a near-threshold result. Mark the test mixed or hot-only and note other open fixtures, because total fixture discharge and heater flow answer different questions. A single-handle fixture set toward hot can still have a temperature limiter or mixing path; verify its arrangement before treating its entire discharge as heater flow.
For ATI-540H, the normal INFO display cycles through inlet temperature, outlet temperature and flow in that order, according to 2000534710 Rev. C, p. 48. Record the three readings during the same steady draw. Reconcile mixing, other taps, recirculation and instrument resolution before interpreting disagreement with a bucket test as a flow-sensor failure.
Worked example: a low-flow draw at an ATI-540H
Use a selected mixed draw of 0.70 GPM at 105°F, supplied by 60°F cold water. Compare heater outlet conditions of 140°F and 120°F; the first is a configured calculation case, and the second is the factory default in the ATI-540H guide. The building's approved temperature target and scald protection govern any actual setting change.
Multiply mixed flow by the fraction of the temperature rise supplied by hot water. The mixing equation is Qhot = Qmixed × (Tmixed − Tcold) / (Thot − Tcold).
Anvilfield estimates the hot-side demand needed to deliver 0.70 GPM at 105°F as 0.39 GPM with a 140°F source and 0.53 GPM with a 120°F source. Compared with the published flow values, the first nominal demand is below startup and just below continuation; the second exceeds startup. Use the calculated demand to choose the next measurement, then confirm actual flow and burner response at the installed setting.
Collection uncertainty matters near the boundary. With a selected volume uncertainty of ±0.01 gallon on the 30-second collection, mixed flow spans 0.68 to 0.72 GPM. Holding temperatures fixed, Anvilfield estimates hot-side demand of 0.38 to 0.41 GPM at 140°F, crossing the continuation boundary, versus 0.51 to 0.54 GPM at 120°F. Record thermometer resolution and repeated readings on the actual job as well.
Method: Anvilfield estimates use the selected flow and temperature inputs, a steady mixing balance, equal water heat capacity, negligible pipe losses and no recirculation or crossover contribution. Operating references are A. O. Smith 2000534710 Rev. C, pp. 46-48 and 64, and AOSRG46835, April 2023, p. 2, checked November 5, 2026. Calculations retain full precision and display flows to two decimals; compare predicted demand with actual controller flow and outlet temperature. A technician controls any setting change, verifies scald protection and preserves the facility's water-management temperatures.
| Input / result | 140°F outlet case | 120°F outlet case | Source / calculation |
|---|---|---|---|
| Cold supply | 60°F | 60°F | Published inlet curve value, S8 p. 64 |
| Mixed fixture target | 105°F | 105°F | Selected calculation input |
| Mixed fixture flow | 0.70 GPM | 0.70 GPM | Selected calculation input |
| Collection over 30 seconds | 0.35 gal | 0.35 gal | 0.70 × 30 / 60 |
| Hot fraction | 56.25% | 75% | Temperature mixing balance |
| Calculated hot-side demand | 0.39 GPM | 0.53 GPM | 0.70 × hot fraction |
| Demand range with selected ±0.01 gal collection uncertainty | 0.38 to 0.41 GPM | 0.51 to 0.54 GPM | 0.68 to 0.72 GPM mixed flow; temperatures fixed |
| Against ATI-540H startup | Below 0.5 GPM | Above 0.5 GPM | S8 p. 46 |
| Against ATI-540H continuous firing | Nominally below; uncertainty spans 0.4 GPM | Above 0.4 GPM | S8 p. 46; collection sensitivity above |
| Published maximum at 60°F inlet / 120°F outlet | Not used for this outlet setting | 6.3 GPM | S8 p. 64, 540 chart |
| Diagnostic priority | Verify actual hot-side draw and mixing | If still cold, continue beyond low-flow branch | Anvilfield interpretation |
Which Rheem codes apply to IKONIC?
Rheem AP23209 Rev 03 identifies A011 as failure to detect flame and A012 as flame loss after ignition. Record whether heat ever began, how long it lasted and which other gas appliances operated during the event.
A029 directs the condensate-trap and drainage branch: AP23209 Rev 03, p. 45, describes a full trap or failure to detect its water level. The service path includes drainage, connections and sensing, so the code alone does not prove a blocked drain. A090 identifies detected venting blockage and leads the technician through vent, air-filter and inlet-pressure checks. Observers retain visible routing, leakage, exterior obstruction and weather conditions; drain disassembly and combustion work remain service tasks. The IKONIC technical manual, pp. 45 and 60, governs those paths.
Rheem IKONIC T111 is a maintenance reminder under AP23209 Rev 03, p. 64, while A. O. Smith 111 is an ignition-failure code under 2000534710 Rev. C. Rheem calls for draining and flushing and warns of eventual protective shutdown; complete that service before clearing T111.
AP23209 Rev 03 sets the service alert at 500 combustion hours by default, offers 750- and 1,000-hour selections, and discourages changing the default. Combustion hours accumulate during firing; they are not calendar years or a universal descaling interval. Record service hours and the prior maintenance date together.
With no code and no heat, technical-manual p. 37 begins with demand, enabled state, low or absent flow, inlet debris and sensing. Establish those conditions before selecting a repair. Keep codes from other Rheem generations, including bare 11, 12 or P1, tied to those generations' manuals.
Which A. O. Smith codes apply to ATI-540H?
The ATI-540H troubleshooting list in 2000534710 Rev. C assigns 111 to ignition failure, 121 to loss of flame and 991 to imperfect combustion. For 991, stop repeated firing trials and arrange the gas, air, vent and combustion service branch.
A. O. Smith's 2000534710 Rev. C assigns code 311 to the heat-exchanger thermistor on the 540 model but to the outlet thermistor on 240 and 340 models. The same guide assigns 331 to the 540 outlet thermistor. Its 441 flow-sensor and 651 flow-adjustment entries carry an Easy-Link-system-only qualifier, so a single-unit flow complaint does not justify assigning either code.
Can warm incoming water explain no ignition?
A. O. Smith 2000534710 Rev. C says the heater will not activate when incoming water is too close to the set temperature; its no-ignition checklist gives no numerical temperature difference for that condition. Record inlet, outlet and setpoint together, especially with preheated supply or a return loop. If inlet and outlet are already near target but the fixture stays cold, compare the distribution path and mixing arrangement.
The same no-ignition checks include low flow, a dirty inlet filter, reversed connections and cross-plumbing. A complaint beginning immediately after installation or plumbing work warrants a connection and configuration review before part replacement. The following selected matrix retains the model qualifiers from the three linked model manuals. Each code identifies a diagnostic branch, not a part to order; use its linked manual for the complete fault list and test sequence.
| Exact display | Applies in this article to | Document and printed location | Detected condition / listed meaning | Record / service branch |
|---|---|---|---|---|
| E003 | Navien NPE-2 user-manual scope | S3 p. 17, v1.0, 2020 | Ignition failure | Demand/supply state; ignition diagnosis |
| E012 | Navien NPE-2 user-manual scope | S3 p. 17 | Flame loss | Whether heat started before failure; supply/air/flame-proving diagnosis |
| E110 | Navien NPE-2 user-manual scope | S3 p. 17 | Abnormal air pressure | Exterior vent condition and weather; air/vent diagnosis |
| E439 | Navien NPE-2 user-manual scope | S3 p. 17 | Abnormal flow-sensor operation | Controller flow and fixture draw; flow-sensing service |
| A011 | Rheem IKONIC RTGH-S11i / SR11i | S5 pp. 38-39, AP23209 Rev 03 | Flame not detected | Startup/alarm; gas/ignition/flame service |
| A012 | Rheem IKONIC RTGH-S11i / SR11i | S5 pp. 41-42 | Flame lost after detection | Time to loss; other appliances; supply/flame service |
| A029 | Rheem IKONIC RTGH-S11i / SR11i | S5 p. 45; S6 p. 93 | Condensate trap full or water level not detected | Visible routing/leakage; trap, drainage and sensing service |
| A090 | Rheem IKONIC RTGH-S11i / SR11i | S5 p. 60; S6 p. 93 | Detected venting blockage | Exterior obstruction and weather; vent/filter/dynamic-pressure checks |
| T111 | Rheem IKONIC RTGH-S11i / SR11i | S5 p. 64 | Maintenance reminder; eventual shutdown | Service hours and maintenance record; maintenance branch |
| 111 | A. O. Smith ATI-540H | S8 p. 55, Rev. C | Ignition failure | Startup/ignition observations; gas/ignition diagnosis |
| 121 | A. O. Smith ATI-540H | S8 p. 55 | Loss of flame | Whether burner started; flame/supply diagnosis |
| 311 | A. O. Smith 540, within ATI-540H scope | S8 p. 55 | Heat-exchanger thermistor, 540 | Thermistor checks; 240/340 meaning differs |
| 331 | A. O. Smith 540 only | S8 p. 56 | Outlet thermistor failure | Inlet/outlet readings and code; sensor service |
| 441 | A. O. Smith Easy-Link installation in cited revision | S8 p. 56 | Flow-sensor failure, Easy-Link qualifier | Parent/child identity; linked-system sensing |
| 991 | A. O. Smith ATI-540H | S8 p. 56 | Imperfect combustion | Stop firing trials; gas/air/vent/combustion service |
Is it a cold-water sandwich, crossover or recirculation fault?
A restart sandwich is hot-cool-hot delivery after a stopped draw resumes: warm water remains downstream, cooler water passes during restart, then heated water arrives. An initial wait while a cooled pipe clears is a different sequence. Repeated cold interruptions during an uninterrupted draw require simultaneous heater-flow, heating-state and fault observations.
Navien describes the A2 buffer and pump arrangement as its response to cold-water sandwich and delivery delay in the condensing tankless practical guide.
A hot heater outlet with a cold fixture directs attention to distribution and mixing. A failed cartridge can admit cold water downstream, while a return check-valve problem can change the flow path. Compare near-heater outlet, affected fixture and return temperature under the same draw condition, then use mixing-valve and scald-control diagnosis.
Which return arrangement is installed?
Identify whether the recirculation loop uses a dedicated return or an intentional thermostatic crossover that returns water through the cold line. The crossover's intended function differs from leakage through a defective mixer; temperature alone cannot identify the failed device. Record a piping sketch and follow recirculation return, balancing and controls for the design questions.
Check the recirculation schedule and demand-control state against the complaint time. A pump that is intentionally off and a failed pump can leave the same cooled branch; record the commanded state before assigning a hardware fault.
An active uncirculated fixture branch explains a delivery wait. An unused or abandoned dead leg creates a separate stagnant-branch issue.
Anvilfield's crossover test interpretation requires a technician to account for returns, crossover devices, multiple heaters and residual pipe pressure before interpreting hot-side flow with the heater's cold supply isolated. Short residual drainage differs from a sustained alternative supply path. Save valve positions and the piping sketch with the result so another technician can reconstruct the test.
Why do winter weather and large draws change the answer?
A. O. Smith's 540 output chart in 2000534710 Rev. C, p. 64, gives 4.7 GPM at 40°F inlet and 120°F outlet, and 6.3 GPM at 60°F inlet and 120°F outlet. These chart values assume a properly sized gas line. The corresponding temperature rises are 80°F and 60°F. Colder incoming water therefore reduces available flow at the same delivery target; use the actual inlet temperature to size hot-water capacity at the required temperature rise.
Record the simultaneous fixture load, outlet target and altitude configuration before calling a unit undersized. A heater that starts reliably at a small draw but loses delivery under a large draw needs an output and supply comparison.
Natural-gas inlet pressure is 3.5 to 10.5 in. WC under Navien NPE-2 Installation Manual v2.0, January 2026, versus 4.0 to 10.5 in. WC under Rheem IKONIC AP23209 Rev 03 and A. O. Smith ATI-540H 2000534710 Rev. C.
Propane inlet pressure is 8.0 to 13.0 in. WC under Navien NPE-2 Installation Manual v2.0, January 2026, and Rheem IKONIC AP23209 Rev 03, versus 8.0 to 14.0 in. WC for the factory-propane models covered by A. O. Smith 2000534710 Rev. C, p. 29. The ATI-540H-N in this comparison is natural gas; that manual warns against converting it to propane. A qualified technician measures static and loaded inlet pressure at the heater with simultaneous gas loads recorded, using the installed fuel's limits rather than manifold-pressure values.
A. O. Smith 2000534710 Rev. C, p. 50, requires electrical power for freeze protection and limits that protection to internal heater piping. Navien NPE-2 User's Information Manual v1.0, p. 15, also requires electrical supply and identifies gas supply as additional freeze protection for A2 models. Record an outage or exposed piping and follow external-pipe freeze protection; suspected freezing or leakage ends firing trials. Follow the model's thawing and leak-inspection instructions before restoring operation.
When do maintenance and resets belong in diagnosis?
Navien's NPE-2 user's manual calls for annual intake and vent inspection; A. O. Smith 2000534710 Rev. C recommends an annual qualified check and annual vent and burner inspection. Rheem AP22745 Rev 04 calls for flushing annually or as professionally recommended, with water conditions and average usage driving frequency.
Record hardness, inlet-filter condition, prior flushing, usage and any service-hour reminder. Debris or scale becomes a supported service finding when inspection and operating evidence point to it. A cold fixture, interrupted electrical supply or insufficient hot-side demand needs its own diagnostic path even when maintenance is overdue.
Keep the cleaning procedure in water heater maintenance and tankless descaling and the supply-water response in water treatment and hardness control.
Photograph and transcribe the code before resetting. Navien's user's manual provides a Back-button reset for minor issues, while recurring faults continue through the relevant diagnostic path. Use only the installed model's documented reset when no stop condition exists; clearing an IKONIC T111 reminder follows its prescribed maintenance. Save previous reset history because an intermittent fault that disappears during the visit still needs a defined next test.
What should the service quote include?
Separate diagnosis, repair authorization and verification in the service quote. List travel, parts, indicated descaling, vent or condensate corrections, gas-piping work and permits as distinct scope items. Access, intermittent operation, parts availability and the required outage window determine the restoration schedule.
Confirm exact part applicability and manufacturer claim authorization before applying warranty credit. Navien's January 2026 Installation Manual, final service page, requires technical-support preauthorization for repairs; preserve the claim reference with the work order.
How do you write a public-facility scope?
A public-facility scope should identify every heater model, the outage window, the diagnostic tests and the records required at closeout. Estimators building a public-facility water-heater service pipeline find agency plumbing bids and past awards through PorchRocket Bid Control. Include access arrangements and temporary hot-water requirements in the work package.
Use equipment counts and plumbing takeoff to organize assets and tasks, and the service labor and dispatch framework to separate diagnosis from approved repairs.
| Work stage | Include in scope | Evidence before advancing |
|---|---|---|
| Diagnosis | Reproduce complaint; record model, flow, temperatures and codes | Finding tied to the installed manual, or a defined next test |
| Repair authorization | Exact part or correction; access; required outage; warranty reference | Written approval for the identified work |
| Return to service | Repeat original fixture, restart and simultaneous-load conditions | Recorded delivery target met, safety checks completed and remaining faults disclosed |
Does no hot water mean the heater needs replacement?
Repair a confirmed fault when the unit can meet operating requirements and the applicable part is available. Compare replacement scope when a failed heat exchanger, unavailable parts or unresolved capacity requirements drive the decision. A discontinued support listing alone does not establish that a serviceable heater needs replacement; flooded equipment follows the manufacturer's replacement or inspection instructions.
Keep intermittent diagnosis and repair authorization separate. When delivery remains unresolved, record the temporary hot-water arrangement, next test, responsible party and return date.
What should you record before handing the job over?
Record identity, symptom sequence, observations, units and disposition before the evidence changes. Stop conditions end observation; below-threshold draw enters the flow branch; adequate confirmed flow without heat enters model diagnostics; a hot outlet with a cold fixture enters distribution and mixing diagnosis.
Safe observation checklist
- ☐ Stop for gas odor or a CO alarm; make calls and record observations after reaching safety.
- ☐ Photograph the complete model, series, serial, fuel or conversion label and literal display code; preserve every prefix and suffix.
- ☐ Record one-fixture versus building-wide failure and whether it occurs at startup, during continuous use, after restart or with simultaneous demand.
- ☐ Capture accessible enabled state, heating indicator, safe fixture temperature, collection volume and duration; identify mixed versus hot-only flow and other open taps.
- ☐ Note outage, freeze exposure, visible vent or condensate conditions, maintenance history and return configuration; hand over without opening the cabinet or clearing evidence.
Technician handoff record
Blank operating readings mean “not measured,” never zero. Attach the governing manual revision and printed page, instrument resolution, repeated readings and before/after test conditions.
| Field | Entry | Use |
|---|---|---|
| Site and asset | Building, room, asset ID, date/time | Identify equipment |
| Identity | Manufacturer; full model; series; serial; fuel; conversion label | Select correct instructions |
| Manual | Document number, revision, URL, printed page | Preserve provenance |
| Installation | Indoor/outdoor; elevation setting; single/cascade; return/crossover sketch | Preserve applicability |
| Complaint | Startup / continuous / restart / simultaneous use; affected fixtures | Reproduce the failure |
| Literal code | For example, T111, not 111; photograph | Avoid cross-brand mistranslation |
| Display and heating state | Powered/enabled; flow display; flame on/off; event timing | Distinguish demand from firing |
| Flow method | Gallons/seconds; mixed/hot-only; controller flow; resolution/repeats | Judge flow margin |
| Temperatures | Cold inlet, heater outlet, affected fixture, return if present; °F | Compare rise and distribution |
| Technician supply readings | Static/dynamic gas pressure in in. WC; water pressure; electrical supply; test state | Test supply against model limits |
| Conditions/history | Outage, freeze, visible blockage/leak, hardness, filter/flush date, service hours | Identify trigger and maintenance branch |
| Work and authorization | Tests; finding; part; manufacturer claim; authorization | Make repair traceable |
| Closeout | Target; original draw/restart/load repeated; flow/temperature; heating state; code; disposition; next action/date | Verify service or define remaining fault |
Anvilfield's closeout method repeats the complaint-producing draw and comparison fixture with flow, temperatures, heating state and code status recorded. Repeat stop/restart timing for a sandwich complaint and the recorded simultaneous load for a high-demand complaint. Accept the work when delivery meets the recorded job target throughout that sequence; write down any departure and the next action.
A vanished error message alone does not establish restored delivery. An unresolved intermittent fault needs its remaining test, responsible party and next service date in the handoff, so the next visit begins with evidence rather than another reset.
Review and citation
Reviewed by Anvilfield on November 5, 2026. Update record, 2026-11-05: Rechecked the twelve primary sources; clarified flooded-heater disposition, fuel applicability and condensate fault interpretation; added service-scope evidence and measurement checks.
When citing a comparison, include its evidence-unit fragment and governing manual revision.
How to cite this page: Anvilfield, No hot water from a tankless heater? Navien, Rheem and A. O. Smith checks, 2026, https://anvilfield.com/field-guides/plumbing/tankless-water-heater-no-hot-water-model-matrix/
FAQ
Why is my tankless water heater running but not heating?
A powered display does not prove heating; compare actual through-heater flow, heating state and the exact model's fault code.
What is the minimum flow for a Navien NPE-180S2?
Navien's January 2026 NPE-2 Installation Manual lists 0.5 GPM for the S2; the A2 low-flow option is separate.
What is the minimum activation flow for Rheem IKONIC?
AP23209 Rev 03 gives 0.4 GPM activation and 0.26 GPM extinction for RTGH-S11i and RTGH-SR11i.
What flow starts an A. O. Smith ATI-540H?
Its Rev. C Owner's Guide specifies 0.5 GPM at the default temperature to start and 0.4 GPM to continue firing.
Does a 111 code mean the same thing on every tankless heater?
A. O. Smith ATI-540H code 111 means ignition failure; Rheem IKONIC T111 is a maintenance reminder. Preserve the prefix and model.
Why does my tankless heater work only when two taps are open?
The combined hot-side draw can cross the model's startup threshold; confirm heater flow before selecting a repair.
Why does my tankless shower go hot, cold and hot again?
A restart sandwich differs from a continuous-draw dropout; record when the interruption occurs and what the heater does at that moment.
Will descaling fix no hot water?
Descaling addresses scale where indicated; low activation flow, interrupted power, fuel faults and cross connections require their own diagnostic paths.
Does a gas tankless water heater work during a power outage?
The scoped gas models need electricity; ATI-540H 2000534710 Rev. C specifies 120 VAC, 60 Hz in its no-hot-water checks.
Why is my tankless heater fan running after the tap closes?
A. O. Smith 2000534710 Rev. C, p. 52, describes 15 to 70 seconds of fan operation after the draw stops for exhaust purging and readiness to reignite. Fan noise alone does not prove that the burner is heating water.
Why is only one shower cold when other taps get hot?
Compare heater flow and outlet temperature during that shower's draw; low hot-side demand, a restriction or a mixing-valve fault can affect one fixture while another works.
Should I reset a tankless water heater with no hot water?
Save the exact code and symptom first, then use only that model's documented reset when no stop condition exists; a recurring fault requires its diagnostic branch, and an IKONIC T111 reminder calls for the prescribed service before clearing.
People also ask
Sources checked
- S1. Navien, NPE-180S2 downloads. Manufacturer model and document register; checked 2026-11-05.
- S2. Navien, NPE-2 Installation Manual, Version 2.0, January 2026, 20049624B. Printed pp. 7, 24-27 and final service page: flow, fuel pressures, recirculation and repair authorization. Checked 2026-11-05.
- S3. Navien, NPE-2 User's Information Manual, Version 1.0, 2020, 20049624A. Printed pp. 5, 15-18: inspection, freeze protection, troubleshooting and codes. Checked 2026-11-05.
- S4. Navien, NPE-2 Specification Sheet, 1-NPE2-SS-001-1.1. Flow footnote and A2 ComfortFlow configuration. No calendar edition printed. Checked 2026-11-05.
- S5. Rheem, IKONIC Technical Training and Service Manual, AP23209 Rev 03. Printed pp. 7, 35, 37-45, 60, 64: flow, pressures, service hours and selected fault paths. Checked 2026-11-05.
- S6. Rheem, Condensing Tankless Water Heater Use and Care Manual, AP22745 Rev 04. Printed pp. 84, 87, 92-93 and safety sections: condition-based maintenance and owner service response. Checked 2026-11-05.
- S7. A. O. Smith, ATI-540H 100 model support page. ATI-540H-N, Series 100 installed-equipment support; discontinued status and governing manual link. Checked 2026-11-05.
- S8. A. O. Smith, On-Demand Water Heater Installation Manual and Owner's Guide, 2000534710 Rev. C, 68A161-7. Printed pp. 6, 29, 31, 46-48, 50-56 and 64: flooded-heater replacement, fuel applicability, supply, flow, display, diagnostics and capacity. Checked 2026-11-05.
- S9. A. O. Smith, Commercial-Grade Residential/Commercial Gas Water Heaters, AOSRG46835, April 2023. Printed p. 2: model scope, startup and continuous flow, gas-pressure limits. Checked 2026-11-05.
- S10. Navien, Condensing Tankless Water Heaters: A Practical Guide. Undated live manufacturer guidance: A2 buffer, pump and cold-sandwich rationale. Checked 2026-11-05.
- S11. U.S. Consumer Product Safety Commission, Carbon-Monoxide-Questions-and-Answers. Undated live agency guidance: CO alarm exit, emergency call and reentry response. Checked 2026-11-05.
- S12. A. O. Smith, legacy gas-tankless UEF specification library. Manufacturer provenance for AOSRG46835 and the installed ATI/ATO family. Checked 2026-11-05.