Field glossary · property
Contemporaneous
Contemporaneous records are made at or near the event while the recorder's knowledge is fresh. Preserve the event time, the record's creation time and any later upload or correction as separate facts. A delayed sync does not turn an existing field note into a newly observed event, and a recent file timestamp does not establish when the recorded work occurred. The author and the basis of knowledge belong with the timing.
Created at the time of the work by someone with knowledge, the quality that makes a record hard to challenge in a dispute
Keep observation, entry and upload times separate
Federal Rule of Evidence 803(6), in the rules effective December 1, 2025, describes business records made at or near the event by someone with knowledge or from information supplied by that person. The connection is between the event, the knowledgeable source and the record. A timestamp without an identified source leaves part of that connection unexplained.
For an observation at 14:10 entered at 14:17, retain both times. If the device uploads the note the next morning, preserve that synchronization event as a third field. The seven-minute entry interval remains visible even though the office received the file later. Give the times a date and time-zone context so a turnover export preserves the same sequence the field record showed.
Routine records and later recollections have different foundations
Rule 803(6) also addresses keeping the record in a regularly conducted activity and making such records as a regular practice. Timing is one condition within that framework. A daily record made by the assigned observer follows a different creation history from a narrative assembled after a dispute begins.
Rule 803(5) addresses a different situation: the witness once knew the matter but can no longer recall it well enough to testify fully and accurately. The record must have been made or adopted while memory was fresh and accurately reflected that knowledge. Under this rule an admitted record can be read into evidence; it is received as an exhibit only when an adverse party offers it. Mark a later recollection with its true creation date and source instead of merging it into the daily log.
Rule 803(6) also requires a foundation through the custodian, another qualified witness or an allowed certification, and addresses indications of untrustworthiness. A seven-minute entry interval explains timing; it does not establish those other conditions. Retain the routine logging practice and source of knowledge with the record.
- Knowledgeable source and creation at or near the event, Rule 803(6)(A)
- Record retained through a regularly conducted activity, Rule 803(6)(B)
- Making that kind of record as a regular practice, Rule 803(6)(C)
Correct the record without rewriting its chronology
NIST SP 800-86 explains that file creation, modification and access timestamps describe different filesystem events, and copying can change a file's creation time. The date displayed on a file in a turnover folder can therefore describe the copy operation. Preserve the originating field record and its history alongside the delivered report.
A correction should identify the original entry, the corrected fact, who made the correction and when. Keep the earlier version recoverable so the sequence remains understandable. Connect these records to the photo documentation and proof-packet workflow. A reviewer then sees what was known during the work, what was recorded shortly afterward and what was added later.
Distinctions
- Late entry
- An entry made after the event with the event time and actual entry time both shown. Changing only the displayed date cannot establish that the note existed during the work.
- Chain of custody
- Tracks handling after an identified item exists. It answers a different question from how close creation was to the event.
Frequently asked questions
Can an offline field note be contemporaneous?
Its saved creation history can show that it was entered near the event. Keep that history distinct from the later transmission or server-receipt time.
Is a late correction useful?
An attributed correction improves the record when it preserves the original and states the correction time and basis. It should remain identifiable as a later change.