Recurring revenue
Recurring revenue comes from continuing service commitments and belongs in a separate measure from one-time repairs, installations, and installment payments for finished work. Monthly recurring revenue, or MRR, puts active agreement fees on a common monthly basis; annual recurring revenue, or ARR, annualizes that base. Track changes in those measures alongside delivered-service revenue and collections so billing schedules do not disguise growth, discounts, or cancellations.
Revenue you can predict because it repeats on a schedule, from renewing agreements, rather than from one-off transactions
Normalize annual and monthly agreement fees
Chargebee's MRR documentation divides an annual subscription amount by 12 to express it as monthly recurring revenue. Apply that normalization to a mixed maintenance portfolio before adding its active fees. Billing an annual contract in one month does not make the entire fee part of that month's recurring run rate.
Twenty active HVAC agreements at $2,400 annually contribute $4,000 of MRR. Ten agreements billed at $150 monthly add $1,500. The portfolio has $5,500 MRR and $66,000 ARR. These figures describe the active fee base on the measurement date. Keep seasonal delivery costs on their actual calendar rather than treating the normalized monthly fee as a monthly labor budget.
Stripe describes ARR as the annualized value of the current recurring base at unchanged customer and pricing levels. It therefore answers a different question from the revenue already earned during the last twelve months. The service-agreement business guide covers delivery and accounting; the run rate measures the size of the continuing fee base.
Remove setup charges and document discount treatment
Chargebee excludes setup fees, trial charges, and taxes from its MRR calculation. An initial equipment inventory or corrective repair sold with a maintenance plan should have its own revenue classification. Repeated payments toward that completed job do not create another continuing service commitment.
Stripe Billing Analytics always subtracts permanent recurring discounts from MRR and provides settings for other recurring and one-time discounts. Record the chosen treatment with the report. Two exports prepared with different discount settings can disagree even when the customer list and invoices are identical.
Keep future starts outside the active run rate
Chargebee excludes subscriptions in Future and In Trial status from MRR. For an agreement register using the same active-service basis, a signed $12,000 annual contract starting December 1 contributes no active MRR on November 5. At activation it adds $1,000 MRR and $12,000 ARR. Until then, record the signed commitment in the future-start schedule.
Store the effective service date separately from the signature date and invoice date. That lets the report distinguish sales booked for next season from the fee base serving customers today. A deposit received before activation belongs in the cash report without advancing the agreement's service start.
Explain a flat total with an MRR movement report
Stripe's recurring-revenue guidance separates new subscriptions, expansion, contraction, and churn when explaining movements in MRR. For a contractor, expansion includes a larger recurring equipment scope or a renewal increase; a separately sold replacement remains project revenue.
An opening $10,000 MRR base gains $800 from new agreements and $500 from scope expansions, then loses $300 to reduced scopes and $1,000 to cancellations. Closing MRR is still $10,000. The unchanged total conceals $1,000 in canceled recurring fees that new sales and expansion had to replace.
Carry an agreement identifier and effective date behind each movement. A property leaving the portfolio, a price reduction, and a missed collection require different operating responses. This detail also makes the recurring base supportable during the succession and exit review.
Distinctions
- Repeat customer revenue
- A customer who orders a repair every year creates repeat business. An active agreement creates a defined continuing fee and service commitment. Track repeat purchases separately from the contracted recurring base.
- Collections
- Collections measure money received. Chargebee explicitly distinguishes MRR from payments received, so a run-rate report needs a separate collections report to show cash performance.
Frequently asked questions
Does a multiyear agreement's full value belong in ARR?
Annualize the active recurring fee. A three-year agreement at $6,000 per year contributes $6,000 ARR, while its three-year contracted value is $18,000. Keep the term value in the contract register rather than adding it to the annual run rate.
Sources checked
Also defined as
- Contracted, predictable income such as service agreements, which raises the multiple