Field glossary · business

Service agreement

A service agreement buys a defined package of work for a named asset list and service term. In a maintenance agreement, twelve units requiring four inspection rounds create 48 unit-level obligations, even when billing occurs monthly. Specify what proves each task complete, which findings require separate repair approval, and who resolves access failures. Those details determine what the technician delivers and what the estimator must fund.

A recurring maintenance contract that keeps you on the equipment on a schedule, cutting no-maintenance failures and false callbacks while adding predictable revenue between installs.

Used across 2 Anvilfield field guides, most in HVAC.
Updated

What must the technician complete under the fee?

Give dispatch a task schedule that connects each asset identifier to an action, its due window, and the evidence required to close it. A filter-replacement row should name the specified filter and quantity; a condition-reading row should identify the measurement and the equipment-specific acceptance range. Attach the technical task list developed through the HVAC preventive-maintenance guide.

Separate included work from findings that need customer authorization. The contract can pay for identifying a failed motor while leaving motor replacement outside the fee. Use distinct statuses so a completed inspection does not close the unresolved repair.

RecordWhat closes it
Scheduled inspectionRequired observations, measurements, and findings recorded for the named unit
Access exceptionAffected task rescheduled or its omission resolved through a documented contract change
Repair recommendationCustomer decision recorded; an approved repair remains open until delivered and verified

Count asset tasks separately from site visits

An agreement covering twelve rooftop units with four required inspection rounds owes 48 unit inspections. If the contractor visits on all four scheduled dates but leaves four unit inspections incomplete, attendance is 100% while unit-inspection completion is 44 / 48, or 91.7%.

Keep the four incomplete inspections visible, with the affected units, access problem, notification, and revised disposition. A denied roof access window does not turn an unperformed inspection into a completed one. Distinguish completion status from responsibility for the interruption and from any resulting price or schedule adjustment.

For tasks due on different intervals, maintain separate due counts. Adding a monthly filter task to an annual coil-inspection task without preserving their due dates produces a total that conceals overdue work. Carry each task's frequency into the maintenance agreement schedule.

Use measurable acceptance criteria in public service scopes

For federal performance-based service acquisitions, FAR 37.602 directs agencies to specify required results rather than methods or staffing hours to the greatest practicable extent. FAR 37.603 requires measurable performance standards for those acquisitions. These provisions govern that federal procurement context; they are a useful drafting model for a private agreement, not a mandatory private-contract form.

For the 48-inspection scope, acceptance records should identify which 44 inspections were completed, the four exceptions, and each remaining due date. A signature confirming attendance cannot supply missing unit records. Staffing and travel hours remain in the contractor's delivery budget even when the customer accepts results by task.

Name the owner of verification and follow-up

FAR 37.604 allows the government to prepare its quality assurance surveillance plan or request a proposed plan from offerors for government consideration. That separates the provider's performance promise from the buyer's method of verifying it. On a commercial agreement, assign the same roles explicitly: technician records, service manager review, and customer acceptance or exception response.

Agree which records accompany each invoice and where unresolved findings remain open. A maintenance task that discovers a failed component can be complete while the separately authorized repair remains outstanding. Keep the completed inspection, the defect notification, the repair decision, and any subsequent test as connected records with different statuses.

At renewal, reconcile added and removed asset identifiers against the task history. Carry unresolved findings forward with their authorization status, so an old repair recommendation does not silently become included maintenance. Feed the revised task quantities into the recurring service program.

Distinctions

Workmanship warranty
A workmanship warranty answers for defective installation under its coverage terms. A service agreement purchases continuing work. A covered installation defect and a scheduled maintenance task need separate records even when one contractor handles both.

Frequently asked questions

Is priority service the same as a repair deadline?

Priority assigns a place in the service queue. A two-hour acknowledgment promise starting when a call arrives at 10 a.m. expires at noon if both times are inside its service window. That promise says nothing about arrival or restoration. Give each promised event its own clock, coverage window, and completion record.