ANVILFIELD Try FieldOS

ASTM International

ASTM C936: concrete paver certificates and acceptance evidence

An interlocking-paver certificate should identify the delivered unit, individual and average test results, and durability evidence for the exposure. C936/C936M-26 is ASTM International’s product specification for those units. It provides factory acceptance evidence; traffic loading, support layers and drainage still have to be resolved in the pavement design.

Current edition: ASTM C936/C936M-26 (2026)
Updated

Official publisher page

Applies to

Hardscape specifiers, paver manufacturers, receiving inspectors and testing laboratories use C936 to document the supplied units. Order the exact product, thickness, finish and color, then connect the manufacturer’s test evidence to that product. A compliant sample of a different unit does not identify the pallet delivered to the site.

Key topics

Read the individual strengths as well as the average

CMHA’s 2022 crosswalk guidance summarizes C936 acceptance as an average compressive strength of at least 8,000 psi, with no individual unit below 7,200 psi. That creates two separate checks. Results of 8,700, 8,600 and 7,000 psi average 8,100 psi, but the 7,000 psi unit misses the individual minimum. Retain all specimen results in the submittal review; an average-only certificate conceals this distinction. The layout guide supplies the installation context after the product is accepted.

Absorption and freeze-thaw tests answer different questions

CMHA PAV-TEC-019, revised 2022, lists a maximum average water absorption of 5% and a maximum individual value of 7% for C936 pavers. Its freeze-thaw summary separately limits surface mass loss to 225 g/m² after 28 cycles or 500 g/m² after 49 cycles under ASTM C1645, with exposure determining water or saline testing. A strength result alone does not establish either of those properties. Request the exposure basis and durability evidence with the product certificate, especially for salted approaches and crosswalks.

Compression reports need specimen preparation details

CMHA PAV-TEC-021-14 explains that ASTM C140 paver testing accounts for specimen thickness-to-width ratio and uses prepared bearing surfaces to distribute compression load. Ask the laboratory report to identify specimen dimensions, capping and the reported strength basis. A change in specimen geometry can change the result without a corresponding change in the manufactured concrete. Keep the tested unit’s shape and thickness attached to the result when comparing products or resolving a disputed delivery.

C936 pavers and C1782 slabs have different strength evidence

CMHA PAV-TEC-024-22 distinguishes C1782 paving slabs, qualified by flexural testing, from C936 interlocking pavers, qualified by compression testing. A slab substitution therefore needs the design and product standard reviewed together. An 8,000 psi compression result alone does not establish a slab’s resistance to bending. The distinction is the manufactured unit and its structural behavior, not whether the pavement has open drainage joints. Keep the product standard beside the unit dimensions on the substitution request.

Purchase appearance separately from laboratory performance

ASTM C936/C936M-26 leaves desired special features, including color, texture, finish and higher strength, for the purchaser to specify. Turn those choices into an approved product description and appearance sample before release. A physical-property certificate cannot settle whether the delivered blend matches the selected color or surface treatment. The acceptance file should let the inspector answer both questions without treating an appearance dispute as a failed strength test.

How it is used in the field

At receiving, photograph product and pallet identification, compare unit geometry with the approved selection, and preserve the manufacturer’s certificates. Group delivery observations by identifiable shipment. Record visible damage separately from laboratory conformity so replacement of broken units does not erase the evidence for the undamaged material.

For a crosswalk submittal, carry the accepted product identifier onto the pavement section and purchase order. CMHA’s crosswalk guidance recommends units at least 80 mm thick for that application. This application recommendation does not assign every C936 product the same traffic capacity. The paver installation guide connects the selected units to base, bedding and restraint.

A submittal review should finish with a traceable disposition: product accepted, additional property evidence requested, or identified units rejected. Include the C936 edition stated in the contract and the edition used on each report. That keeps an older test report distinguishable from a current-edition certification without discarding its underlying measured results.

Municipal crosswalk and plaza replacements also create paver packages; PorchRocket Bid Control tracks public paving bids and early signals in agency capital plans.

Frequently asked questions

Does a high compressive strength prove a paver will resist deicing exposure?

Strength and freeze-thaw durability are separate properties in CMHA’s C936 summary. Use durability evidence with the stated exposure medium and test history for the units being supplied.

What should an estimator request before approving a substitution?

Request the exact unit dimensions, finish, color, individual and average physical-property results, durability evidence and the standard edition claimed. Compare those with the approved pavement section and appearance selection.

Does C1782 mean a unit is a permeable paver?

C1782 identifies segmental concrete paving slabs. CMHA treats permeable interlocking pavement design separately from its slab guidance. Select the unit standard from the product classification, then specify the joints, bedding and drainage section for the intended pavement system.

Sources checked