Cold roof
A cold roof limits heat reaching the snow-covered outer deck so runoff is less likely to refreeze at the eave. PNNL recommends R-60 or more for vented attics in climate zones 5 and higher and a clear 2-inch ventilation path in its ice-dam prevention details. Locate that path on the section: a vented attic and a ventilated over-roof above a conditioned attic are different constructions.
A deck held near outdoor temperature by air sealing, insulation, and ventilation so snow does not melt unevenly
Locate the cold surface in the roof section
In a conventional vented attic, the thermal boundary lies at the ceiling. In a ventilated over-roof, insulation can remain at the roof deck while a separate exterior air channel runs beneath the outer sheathing. Draw these as different sections: an attic volume and a narrow roof channel do not have the same airflow geometry.
The Pacific Northwest National Laboratory ice-dam guide recommends R-60 or greater for unconditioned, ventilated attics in climate zones 5 and higher. This is its ice-dam prevention recommendation. Identify the insulation location and local energy-code requirement separately rather than treating the R-value as a complete cold-roof specification.
Follow each ventilation channel around interruptions
PNNL recommends a 2-inch ventilation airspace for the roof-channel arrangements described in its ice-dam prevention guidance. Nominal furring depth alone does not prove a continuous route: blocking, insulation, roof windows, and intersecting valleys can interrupt individual channels.
Trace each channel from inlet to outlet at dormers, valleys, blocking, and roof windows. Record the clear depth at the restriction rather than the nominal furring size. A 2-inch cavity reduced to 1/2 inch by displaced insulation has lost three-quarters of its clear depth at that point, even if the ridge opening is unobstructed.
Keep heat sources inside the thermal boundary
PNNL recommends locating mechanical equipment in conditioned space instead of an unconditioned attic to reduce localized heat input. A high insulation value across most of the ceiling does not compensate for a warm duct, an unsealed chase, or equipment losses concentrated below one patch of roof.
Compare a repeated snowmelt strip with the interior service layout. Document whether it follows a chase, duct branch, or ceiling penetration and whether nearby roof areas retain snow under the same weather. Bring that location-based evidence to the ice-dam management guide so the retrofit addresses the concentrated heat path.
Distinctions
- Cool roof
- A cool-roof submittal reports solar reflectance and thermal emittance. A cold-roof survey records insulation location, clear ventilation depth, and the winter heat pattern. Keep those acceptance records separate when one roof must provide both functions.
- Unvented attic
- Unvented describes the attic ventilation arrangement. An unvented conditioned attic can sit below a separate ventilated outer roof, so attic terminology alone does not describe the outer deck.
Frequently asked questions
Does adding a ridge vent create a cold roof?
Only if the assembly also provides usable intake and a connected air path, while controlling heat reaching the roof. An outlet cannot ventilate a sealed or blocked channel.
Is the ventilation gap part of the insulation thickness?
No. Keep the designed airspace clear of insulation. Show the insulation thickness and ventilation depth separately so neither is reduced during installation.
Is R-60 a substitute for air sealing?
PNNL treats airtightness, insulation, ventilation, and removal of localized attic heat sources as separate parts of ice-dam prevention. Insulation depth does not document a sealed chase or an uninterrupted ventilation channel.