Field glossary · process
Corrective action
A corrective action addresses a failure's cause and carries an effectiveness check through the next relevant operating condition. Track installation and verification separately: in a register of 20 actions, 18 completed changes mean 90 percent implemented, while 12 verified fixes mean only 60 percent of the register has demonstrated effectiveness. A signed work order closes the installation task; the specified observation or test closes the effectiveness check.
The fix put in place to prevent recurrence, ranked by the hierarchy of controls and tracked to verified closure
Define the acceptance test before closing the action
The U.S. Department of Energy's project-management lexicon defines a root cause in terms of the factor whose correction would prevent recurrence. That makes the causal link the acceptance question: identify the failure mechanism, specify the change that interrupts it, and state what evidence will show the interruption worked.
For repeated missing fasteners, "crew retrained" records an activity. A revised fastening layout, an inspection hold point, and a check of subsequent installations create observable acceptance criteria. Record the exact condition being checked so the reviewer does not replace a technical criterion with a general impression that the work improved.
Schedule a return to the failure conditions
DOE's description of closed-loop corrective action identifies follow-up at approximately 1, 3, 6, and 12 months after implementation. Those are review intervals in its project-management guidance, not an OSHA deadline for every incident. Their purpose is to revisit the fix after the process has had time to operate again.
A drainage correction completed during dry weather needs evidence during the next relevant rainfall. A revised shutdown procedure needs observation during an actual shutdown. Put the trigger and reviewer in the action record, and retain an open effectiveness check when the necessary operating condition has not yet occurred.
Give the action two dated decisions: implementation accepted and effectiveness accepted. Store the triggering rainfall, operating cycle, or follow-up inspection with the second decision. A reviewer should be able to recover the evidence without inferring success from the absence of another complaint.
Separate completion rate from verified effectiveness
Anvilfield's 20-action register separates three dashboard measures. Report the count and denominator with each percentage so completion cannot stand in for demonstrated effectiveness. An action awaiting the next rainfall or shutdown belongs in an implemented-but-unverified status.
Washington State Department of Labor & Industries directs incident investigators to identify root causes, select corrective actions, and implement them, noting that some actions need more planning time than others. Preserve interim controls during that interval. The incident-investigation guide supplies the investigation workflow; this register tracks what happened after the recommendation.
| Measure | Calculation | Result |
|---|---|---|
| Implemented share of all actions | 18 / 20 × 100 | 90 percent |
| Verified effective share of all actions | 12 / 20 × 100 | 60 percent |
| Verified effective share of implemented actions | 12 / 18 × 100 | About 67 percent |
Distinctions
- Correction
- A correction fixes the immediate defect, such as replacing a missing fastener. Corrective action addresses why the process allowed the defect and verifies the change against recurrence.
- Preventive maintenance
- Scheduled maintenance can prevent deterioration without originating in a failure investigation. It becomes part of a corrective action when it addresses an identified cause and has a defined effectiveness check.
Frequently asked questions
Can an action be implemented but still open?
Yes. Use separate implementation and effectiveness fields. The physical change can be complete while the team waits for a defined operating event or inspection result.
What happens when the same failure returns?
Reopen the causal question and preserve the original evidence. Determine whether the action was implemented as designed, whether it addressed the cause, and whether conditions have changed.
Sources checked
Also defined as
- Datacenter: A specific, owned, dated change that fixes a cause found in the RCA, tracked until it is done and verified