Incident

A jobsite incident is counted as one event even when it injures several workers, damages equipment or interrupts a service. A pallet collapse that narrowly misses the crew still belongs in the incident system. Each employee injury needs its own classification beneath the event identifier. OSHA recordability depends on work-relatedness, new-case status and the applicable recording criteria. Internal reports, OSHA-recordable cases and notifications to OSHA serve different purposes.

An unplanned event that caused or could have caused injury, illness, or property damage; OSHA prefers it over accident

Used across 2 Anvilfield field guides, most in Roofing.
Updated

One event is not one OSHA case

For employers required to keep OSHA logs, 29 CFR 1904.4 first asks whether an injury or illness is work-related and a new case. Apply the recording criteria to each employee after those checks. Under OSHA 1904.29, every recordable case entered on the 300 Log also requires its own 301 Incident Report or equivalent.

A pallet collapse causes new work-related cuts to two workers. One receives wound cleaning and a bandage, with no other recording trigger. The second receives two sutures. Under OSHA 1904.7, the first treatment is first aid and the sutures are medical treatment beyond first aid. The result is one event, two individual injury reports in the company's file and one OSHA-recordable case.

Keep the shared event number on the investigation record and any associated service incident record. Give each employee case its own identifier beneath that event. This preserves the relationship without counting one injured person twice.

What treatment counts as first aid?

OSHA 1904.7 classifies butterfly bandages and Steri-Strips as first aid, while sutures and staples are medical treatment beyond first aid. It also treats massage as first aid and physical therapy or chiropractic treatment as medical treatment. The treatment's identity matters more than whether it happened at the jobsite, a clinic or a hospital.

Under OSHA 1904.7, a nonprescription medicine used at nonprescription strength is first aid; a clinician's recommendation to use it at prescription strength is medical treatment for recordkeeping. Copy the treatment and strength into the case record instead of shortening the outcome to 'released from clinic.'

OSHA 1904.7 excludes diagnostic procedures such as X-rays from medical treatment, but a diagnosed fracture independently makes a qualifying case recordable. Its criteria also capture an employee who loses consciousness after a work injury without receiving treatment. Death, days away and job transfer have separate recording paths; a first-aid decision alone does not close the classification.

Restricted duty includes weekly tasks

OSHA 1904.7 defines routine job functions as activities an employee regularly performs at least once per week. A restriction preventing one of those functions, or preventing the normal full workday, enters the restricted-work test. A worker does not have to lose the main task performed every day.

An electrician who normally handles conduit deliveries each week receives a lifting restriction that continues into the next workday. Spending that day on unrestricted desk tasks does not erase the restriction on a routine field duty. OSHA excludes restrictions confined to the injury day itself from restricted-work recording. Restrictions continuing beyond that day meet the recording criterion when they prevent a routine function or full workday.

When must the 300 and 301 be completed?

OSHA 1904.29 requires the 300 Log entry and 301 Incident Report within seven calendar days after the employer receives information that a recordable injury or illness occurred. A later diagnosis changes the decision when it establishes a recording criterion. For example, learning that an initially bandaged finger is fractured establishes recordability even without additional treatment.

An insurer's form qualifies as an OSHA 301 equivalent only when it contains the same information, is equally readable and understandable, and follows the same completion instructions. A claim number or emailed treatment summary alone does not satisfy those conditions. Keep the classification decision with the records described in the construction safety program guide.

Who records a temporary worker's injury?

OSHA 1904.31 assigns injury and illness recording for temporary or supplied workers to the employer providing day-to-day supervision. Payroll ownership alone does not settle it. The host and supplying employer coordinate so each case appears on one employer's OSHA log.

Record which employer directed the worker's daily activities and which employer accepted the case for its log. That decision keeps a shared jobsite event from disappearing between companies or being counted by both.

Distinctions

OSHA notification
The seven-day paperwork deadline in OSHA 1904.29 does not extend the notification deadlines in 1904.39. Keep the 300/301 completion date and the time OSHA was notified in separate fields. The investigation's event number links them without treating either action as completion of the other.

Frequently asked questions

Does property damage alone belong on the OSHA 300 Log?

The 300 Log records qualifying employee injuries and illnesses. Keep a damage-only event in the internal incident system; damage cost alone does not create a 300 Log case.

Does an emergency-room visit count as a reportable hospitalization?

OSHA 1904.39(b)(9) and (10) distinguish formal inpatient admission for care or treatment from observation or diagnostic testing alone. Record the admission status and purpose of the visit. An emergency-room visit by itself does not establish the hospitalization reporting trigger; the injury can still be recordable.