Burdened labor rate

A burdened labor rate divides employment cost by the hours assigned to recover it. Annual cost of $105,066.80 recovered through 1,760 job-chargeable hours produces $59.70 per hour. Spreading that same cost over 2,080 paid hours produces $50.51. Use the hour basis carried in the estimate, and count paid leave once: fewer chargeable hours raise the recovery rate without changing the employee's wage.

Full hourly cost of a worker: wage plus taxes, insurance, benefits, and PTO, not the bare wage

Used across 2 Anvilfield field guides, most in Electrical.
Updated

Which 2026 payroll taxes belong in employer cost?

IRS Publication 15 (2026) sets the employer Social Security tax at 6.2% of each employee's taxable wages up to $184,500 for the calendar year. The same publication sets employer Medicare tax at 1.45% with no wage ceiling. Those employer shares are additional cost; ordinary employee withholding comes out of the gross wage already budgeted.

IRS Publication 15 (2026) applies FUTA at 6.0% to the first $7,000 of taxable wages. Its maximum 5.4% credit reduces that to 0.6%, or $42 per employee, when state unemployment tax is paid in full, on time and on all FUTA-taxable wages, and the state has no credit reduction. State unemployment tax remains a separate cost with its own wage base and assigned rate.

Turn annual payroll into a cost per job hour

A straight-time staffing plan pays an hourly employee $40 for each of 2,080 paid hours, or $83,200 annually. It assigns 1,760 hours to jobs and 320 hours to paid leave, training and other time recovered through this labor pool. All wages in this build-up are subject to Social Security, Medicare and FUTA; the FUTA calculation uses the full credit.

The insurance and benefit amounts below are annual budget inputs. The $12,480 benefit line pays qualifying employer health-coverage contributions. IRS Publication 15-B (2026) provides an employment-tax exclusion for qualifying accident and health benefits, so the health contribution is an employment cost without being added to taxable wages in this calculation.

Annual cost componentCalculation or budgetAmount
Gross wages2,080 paid hours x $40$83,200.00
Employer Social Security and Medicare$83,200 x 7.65%$6,364.80
FUTA after full credit$7,000 x 0.6%$42.00
State unemploymentAnnual budget$900.00
Workers' compensationAnnual budget$2,080.00
Employer health coverageAnnual contribution$12,480.00
Employment cost to recoverSum of listed costs$105,066.80

Why dividing by paid hours understates this estimate

The annual total divided by 1,760 job-chargeable hours is $59.70 per hour, rounded after division. Dividing by all 2,080 paid hours gives $50.51. Applying that lower rate to only 1,760 estimated job hours leaves $16,164.12 of the annual employment cost unrecovered, using unrounded rates.

The 320 non-job hours are already paid inside the $83,200 wage total. Adding another paid-leave percentage would duplicate those wages. Post the $59.70 rate to the matching hour pool in job costing; recover training or shop time through that pool or through overhead with a matching allocation.

Against the $40 wage, the job-hour rate has a multiplier of 1.4924, or a 49.24% uplift, using the unrounded rate. The paid-hour version has a 26.28% uplift. Calling both figures 'labor burden' without naming the denominator makes two sound worksheets look inconsistent.

Keep taxable pay separate from benefit expense

Give the rate worksheet separate columns for gross pay, taxable wages by tax, employer contributions and recoverable hours. A raise changes wage-linked taxes; a health-premium increase changes the benefit line; fewer chargeable hours change the denominator. Updating those inputs separately explains a rate change without disguising it as a larger installation labor unit.

Distinctions

Billable labor rate
The customer-facing selling rate also recovers the company's pricing requirements. The $59.70 calculated here contains only the listed employment costs, with company overhead and profit priced separately.
Production rate
Installed units per labor-hour determines how many hours a task needs. Employment cost per matching hour determines what those hours cost. Keep the two inputs independently visible.

Frequently asked questions

Should I add the employee's income-tax withholding to labor burden?

No. Withholding reduces the employee's net paycheck from the gross wage already included. Adding ordinary employee withholding again would duplicate wage cost.

Why can two estimators calculate different rates from the same payroll?

One may divide by paid hours while the other divides by job-chargeable hours, or they may recover non-job time in different cost pools. Reconcile annual dollars and annual hours before comparing their hourly results.