ANVILFIELD Try FieldOS

Field glossary · material

Evaporation retarder

Evaporation retarder takeoffs have two volumes: concentrate purchased and diluted solution sprayed to limit water loss during finishing. At EUCOBAR's specified 9:1 water-to-concentrate ratio, 1 gallon of concentrate produces 10 gallons of spray. Its 200 to 400 square feet per gallon coverage refers to that diluted spray. W. R. Meadows requires a separate curing application after surface water dissipates when EVAPRE is used, so the retarder allowance belongs beside the curing allowance.

A monomolecular film sprayed on the plastic surface to slow drying between finishing passes; not a curing compound

Used across 2 Anvilfield field guides, most in Concrete.
Updated

How much concentrate belongs in the sprayer?

W. R. Meadows specifies one part EVAPRE concentrate to nine parts water for most applications in its November 2025 data sheet. That makes ten parts of finished solution. A 1-gallon concentrate container therefore produces 10 gallons for spraying when combined with 9 gallons of water.

Euclid Chemical specifies the same 9:1 water-to-concentrate ratio for EUCOBAR and lists coverage of 200 to 400 square feet per gallon after dilution. The published spread depends on surface texture and wind conditions. Write the word diluted beside the coverage figure on the takeoff; using the concentrate container size as sprayable volume defeats the calculation.

Budget the repeat applications, not just the first pass

A 3,000-square-foot placement sprayed at 300 square feet per gallon consumes 10 gallons of solution, made from 1 gallon of concentrate and 9 gallons of water at that dilution. Repeating the application over the whole area doubles consumption to 20 gallons of solution and 2 gallons of concentrate. A partial-area repeat needs its own area entry.

Count those applications during finishing instead of assuming the initial spray protects every later operation. EUCOBAR's instructions allow additional applications in extreme drying conditions and identify use between dry-shake applications. The consumption record should show the stage and area treated so a high total is distinguishable from an over-concentrated first application.

Put the sprayer's working capacity and the number of area passes on the material sheet used with the hot-weather plan. A partial refill uses the same ingredient ratio as a full tank, while another pass increases the volume needed. Those are different changes to the takeoff.

Shelf life and product names do not transfer between brands

W. R. Meadows gives EVAPRE a one-year recommended use period in unopened indoor storage at 40°F to 90°F. Euclid Chemical lists a two-year shelf life for EUCOBAR in its original unopened package. Similar dilution ratios do not establish the same storage life, so retain the product identity and manufacture or expiry information when consolidating leftover containers.

EUCOBAR's data sheet uses the phrase finishing aid in its title while specifically prohibiting use as a final finishing aid and immediate working of the liquid into concrete. Read the application limitations with the product name. Extra liquid used to chase a closing surface is a different operation from the specified fine spray that limits evaporative loss.

Distinctions

Concentrate coverage
The area treated by the diluted solution made from a container of concentrate. It is not the area covered by spraying the concentrate undiluted.
Surface set retarder
A product intended to delay surface cement hydration for exposed-aggregate work. EUCOBAR's instructions explicitly distinguish it from that product class.
Curing compound
EUCOBAR's limitations prohibit using it as a curing compound. Carry the approved curing material as its own quantity after the finishing-stage sprays.

Frequently asked questions

Does a 9:1 dilution mean nine gallons of finished spray?

Not when the label means nine parts water to one part concentrate. The combined volume is ten parts. Always identify which ingredient appears first in the manufacturer's ratio.

What should the application log say?

Record the product, concentrate and water quantities, treated area, finishing stage, and each repeat application. Those entries distinguish dilution accuracy from the amount of finished solution used on the slab.