ANVILFIELD Try FieldOS

Field glossary · business

PO (purchase order)

A purchase order (PO) records terms issued to a vendor, followed by separate acceptance, receipt and invoice records. In a $10,200 order, $6,375 invoiced plus $3,825 still due for delivery equals the commitment. Treating the invoice and original PO as separate costs overstates the forecast. Keep a customer's incoming PO in the sales record and your supplier PO in purchasing, linked by the job number.

A document authorizing a buy against a job, naming the items, the agreed price, and a tracking number

Used across 2 Anvilfield field guides, most in Electrical.
Updated

When does supplier acceptance create an obligation?

Washington's RCW 62A.2-206 permits an order for promptly shipped goods to be accepted by a prompt promise to ship or by shipment, unless its language or circumstances require another method. Preserve the actual acceptance event and terms; an office PO number alone does not establish them.

Codified FAR 13.004, in FAC 2026-01, treats a federal order responding to a quotation as an offer accepted by the supplier. GSA's FAR Overhaul FAQ ties use of replacement model text to an agency's class deviation. The overhaul's Part 13, issued September 18, 2025, reorganizes the purchasing procedures and covers noncommercial acquisitions. Identify that rule set before using the codified paragraph numbers on a federal order.

Compare the vendor's acknowledgment with the issued terms. Resolve changes to the ship date, substitution or price before marking the order confirmed. Keep the requested date and accepted delivery commitment in separate fields.

Keep customer POs out of the supplier commitment total

A customer's PO authorizes its purchase from your company; your supplier PO authorizes your material buy. Link both through the job without adding the customer's order value to purchasing commitments. The dispatch record needs the incoming customer reference, while accounts payable needs the outgoing vendor order.

What belongs on a measurable PO line?

Codified FAR 13.302-1(b) pairs an ordered quantity or service scope with a determinable delivery or performance date. That is a useful line-writing discipline for a trade purchase: show unit, pack size, destination and accepted submittal revision. Twelve boxes of ten disconnects are 120 pieces; twelve boxes of twenty are 240. An unchanged box count does not preserve the order quantity.

For a service order, record the included visits, travel and deliverables so the vendor's attendance allowance reconciles to the work package. Keep the accepted scope beside the line price.

Reconcile a partial delivery without counting it twice

An order buys 120 disconnects at $85 each before tax, with freight included: $10,200. The first delivery contains 80, but five damaged units are returned for replacement. The receiving record accepts 75, and the approved invoice is $6,375. Forty remain unshipped and five replacements remain due.

The open delivery balance is 45 x $85 = $3,825. Approved invoices of $6,375 plus the $3,825 unbilled balance reconcile to the $10,200 commitment. Adding the full PO to the invoice instead reports $16,575 and counts the same 75 units twice.

Keep the return authorization and replacement obligation open. An invoice for all 80 delivered units needs a $425 adjustment or a documented resolution for the five returned units. Payment of the accepted invoice does not resolve the remaining delivery.

Close revisions, returns and financial balances

Codified FAR 13.302-3(b) identifies a federal PO modification by the original order and a modification number. Preserve that revision trail for substitutions, freight changes and cancellations. Keep the original amount, adjustment and revised commitment visible.

Close the order when remaining deliveries, returns and credits are settled or explicitly canceled. Connect that closure to job expense tracking so purchasing and the cost forecast stop carrying the same obligation at the same time.

Distinctions

Purchase requisition
An internal request for purchasing approval. A requisition number alone does not show that an order was issued to or accepted by a supplier.
Open commitment
The remaining authorized purchase exposure after invoiced amounts, approved cancellations and other adjustments are reconciled. It is distinct from the original face value of the PO.

Frequently asked questions

Do received goods disappear from commitments before an invoice arrives?

Keep their value visible as received but not invoiced. If the 75 accepted disconnects have not yet been invoiced, their $6,375 remains inside the $10,200 order exposure alongside the $3,825 undelivered balance. Receipt changes status; it does not add another purchase.

Should I close a PO after its first invoice is paid?

Only after the remaining delivery and financial obligations are resolved. A partial invoice can be fully paid while the same order still has backorders, replacement goods or credits outstanding.

Sources checked

Also defined as

  • The customer's authorization number, often required for payment

Where this shows up

Related guides

Next step: Search public service work

Back to the full field glossary