ANVILFIELD Try FieldOS

Field glossary · business

Overhead

Overhead is a pool of costs assigned across the jobs or departments it supports. Divide that pool by its defined allocation base: $180,000 spread over 12,000 direct labor hours applies $15 per hour to the work. Keep that assigned cost separate from the amount recovered in customer prices. Comparing applied overhead with actual spending reveals the period's allocation shortfall or excess.

The indirect cost of running the business, spread across all jobs as a markup

Used across 3 Anvilfield field guides, most in Landscaping.
Updated

Start with a cost pool and the work it supports

FAR 31.203(c), in FAC 2026-01 effective March 13, 2026, requires logical indirect-cost groupings and allocation bases reflecting the benefits received by the work. For federal contracts governed by these cost principles, allocation is therefore more than choosing a convenient percentage of sales.

A shared dispatch function supports service calls; a purchasing and receiving function supports material acquisition. Pooling both together can hide different consumption patterns between a labor-heavy service department and a material-heavy installation department. A useful allocation record identifies the accounts in each pool, the activities benefiting from it and the measured base used to distribute the total.

The overhead recovery guide addresses collection through bid pricing. The allocation record explains why a particular job receives a particular share, which is the evidence needed when comparing departments.

Indirect and fixed describe different things

The SBA defines fixed costs by their behavior over an activity range and separates the fixed and variable portions of mixed costs. Direct versus indirect describes assignment to work instead. A shared telephone account can contain a fixed subscription and usage charges while both remain in the business's indirect-cost pool.

Conversely, a fixed monthly trailer rental dedicated to one project can be a direct project charge. The fact that the payment repeats each month does not make it company overhead. Keep cost behavior, job assignment and reimbursement eligibility as separate fields rather than forcing one label to answer all three questions.

Underapplied overhead is a cost allocation shortfall

An HVAC service department budgets $180,000 annual overhead against 12,000 direct labor hours, giving an application rate of $15 per direct labor hour. If actual hours fall to 10,000 and spending remains $180,000, the jobs receive $150,000 of applied overhead. Overhead is underapplied by $30,000; the actual rate for that activity is $18 per hour.

OpenStax's Managerial Accounting defines underapplied overhead by comparing actual and applied cost. Here, $30,000 remains unassigned by the application rate. That is an allocation variance, not proof of a revenue shortfall. Selling prices above the estimated allowances can still recover the full pool; determine recovery from actual revenue and expense totals.

The rate increase comes from the smaller denominator, even though spending did not increase. Track actual pool spending and actual base activity separately. A plan to reduce office expense addresses the numerator; a plan to sell more productive hours addresses the denominator. The two actions have different operating consequences.

Use matching periods for both inputs. Dividing a full year's insurance and office cost by one quarter's field hours creates a rate that represents neither period. Reconcile the hours to the same labor population used when the rate was established, then carry the adjustment into the job-cost report.

A federal billing rate is temporary recovery

FAR 42.704(c), in FAC 2026-01 effective March 13, 2026, allows prospective or retroactive billing-rate revisions by mutual agreement between the contractor and the responsible contracting officer, agency official or auditor. When agreement fails, the contracting officer or cognizant agency official can determine the rate unilaterally. The contractor's revised internal calculation alone does not establish a new invoice rate.

FAR 42.704(b) sets interim billing rates close to the anticipated final indirect-cost rates, adjusted for unallowable costs. Paragraph (d) keeps the interim cost elements and allocation bases from determining the final settlement. A billing rate, the actual internal allocation rate and the settled allowable rate can therefore be different figures.

FAR 31.203(b) bars inconsistent direct and indirect treatment of costs incurred for the same purpose in like circumstances. Apply that consistency when reviewing expense coding: moving a direct job purchase into overhead because its job tag is missing does not establish an allocation rationale. Resolve the originating job and preserve the correction in the ledger.

Distinctions

Labor burden
A labor-burden schedule identifies employee-related costs already attached to labor. The overhead-pool reconciliation must show whether those same accounts have been removed or deliberately allocated through a separate fringe pool.
Markup
An overhead allocation measures assigned cost. A markup establishes a pricing addition. Recovering an overhead amount in a price does not turn that cost into profit.

Frequently asked questions

Should overhead be divided by paid hours or direct hours?

Use the base defined for that pool. A direct-labor-hour rate uses direct hours, including the same population in its budget and actual calculation. Paid leave and administrative time do not become direct job hours just because payroll records them.

Does allocating overhead change a fixed-price contract?

An internal allocation changes the measured job result. It does not itself change an agreed selling price. Keep cost reporting separate from a contractual price adjustment or reimbursable-rate settlement.

Sources checked

Also defined as

  • HVAC: The cost of running the company that cannot be billed to one job: rent, office staff, insurance, software, and the owner's management pay.
  • Electrical: Cost not billable to one job, recovered through the overhead rate rather than a customer invoice

Where this shows up

Related guides

Next step: Find rooftop service accounts

Back to the full field glossary