Labor burden is the employer's labor cost beyond the employee's base wage, allocated to a stated hour basis. A defensible burden calculation separates employer payroll taxes, insurance, benefits, and paid nonworking time, then identifies which costs are already recovered elsewhere. The resulting percentage is meaningful only when its numerator and denominator match the estimator's definition of a paid hour or productive job hour.

The payroll taxes, workers' comp, insurance, and benefits added to the bare wage to get the real hourly cost of labor.

Used across 2 Anvilfield field guides, most in HVAC.
Updated

Use the 2026 employer tax rates, not total withholding

IRS Publication 15 for 2026 sets the employer Social Security rate at 6.2% on covered wages up to $184,500 per employee. The employee's withheld share is not an additional employer labor cost. Apply the annual cap employee by employee rather than spreading an uncapped percentage across every wage dollar.

IRS Topic 751 states that the employer Medicare rate is 1.45%, with no wage-base limit. IRS Topic 751 also states that the 0.9% Additional Medicare Tax has no employer match. Treating that additional employee withholding as burden overstates the employer cost of higher-paid staff.

Below the Social Security wage cap, those two ordinary employer FICA components total 7.65%. Unemployment taxes, workers' compensation, health coverage, retirement contributions, and other employer costs still need their own lines. The 7.65% subtotal is not a complete burden rate.

Calculate burden percentage and productive-hour cost

A technician earns $32 per paid hour for 2,080 paid hours, producing $66,560 of annual base wages. If annual employer taxes, insurance, and benefits total $22,000, annual employment cost is $88,560. Spread across 2,080 paid hours, that is $42.58 per hour; spread across 1,700 productive job hours, it is $52.09 per productive hour.

The $22,000 add-on cost is 33.05% of the $66,560 base wages: burden percentage = employer add-on costs ÷ base wages × 100. Base wages here already include paid leave within the 2,080 paid hours, so adding leave wages again would double count them. Recovering the same annual total over 1,700 productive hours changes the hourly cost, not the annual employer cost.

Reconcile the estimate with the payroll ledger

Map each burden component to its payroll or accounting source and record the date of the rate. Keep employee deductions separate from employer contributions. Check whether workers' compensation is allocated by actual payroll classification and whether the estimate's insurance allowance duplicates overhead recovery.

Carry the chosen hour basis into the overhead and bid-pricing guide. If an estimate multiplies productive hours by a paid-hour cost, it can leave paid nonproductive time unrecovered. If a loaded productive-hour rate already recovers that time, adding a second lost-time factor overstates it.

Distinctions

Selling labor rate
The customer-facing rate also recovers the business costs and profit assigned by the pricing model; burden alone does not set the selling price.

Frequently asked questions

Should overtime use the regular burden percentage?

Recalculate the components affected by the premium wage. Fixed annual benefits do not automatically rise with every overtime dollar, while wage-based taxes and applicable insurance charges follow their own rules and caps.

Sources checked

Also defined as

  • Plumbing: Employer taxes, insurance, workers comp, and benefits on top of wage, often 25 to 45 percent

Where this shows up

Next step: Calculate list economics

Back to the full field glossary