Field glossary · code or standard
ASCE 7
ASCE 7 supplies the structural loading criteria behind a building's design calculations, including environmental loads and the combinations used to check them. The current edition is ASCE/SEI 7-22. When reading a roof submittal, identify the edition, risk category and pressure basis before comparing numbers. A pressure calculated for strength design and an allowable stress design pressure can describe the same wind demand at different numerical levels.
The standard that sets design wind loads and the field, perimeter, and corner zones
Which ASCE 7 edition belongs on the calculations?
ASCE's standards registry identifies ASCE/SEI 7-22 as the current edition and lists Supplements 1, 2 and 3 plus errata as of November 5, 2026. The publisher distinguishes supplements, which extend approved provisions, from errata, which correct the published document. Record the adopted edition and applicable amendments, supplements and corrections in the calculation package.
The full title is Minimum Design Loads and Associated Criteria for Buildings and Other Structures. ASCE publishes the standard; building codes adopt its provisions by reference. Carlisle's March 12, 2025 explanation of the wind changes identifies the 2024 IBC as adopting ASCE 7-22. A jurisdiction's adoption and amendments establish the permit basis. An older permit set does not acquire a new load basis when someone downloads a newer hazard report.
The single-ply attachment guide handles the assembly selection. This edition check comes earlier, when the designer establishes which loading rules the attachment submittal must satisfy.
Why ASD and strength wind pressures do not match
The January 2023 FEMA/NIST design guide for ASCE 7-22 uses 0.6W for wind in basic allowable stress design combinations. ASD means allowable stress design. Its combination with accompanying live and roof loads also applies a 0.75 multiplier to that 0.6W term. Converting W to an ASD wind term is one step within the complete load combination.
A strength-level wind pressure W of -75 psf contributes -45 psf as 0.6W in an ASD combination. Applying 0.6 again produces -27 psf, understating that wind term by 40 percent. Dead load and the other terms still enter through the applicable complete load combination. Keep the wind conversion separate from the resistance and safety factors used in an assembly approval.
In the same FEMA/NIST guide, a wind uplift stability check combines 0.6 times dead load D with 0.6 times wind load W. With 10 psf of resisting dead load and W = -75 psf, the combined demand is 6 - 45 = -39 psf. The -45 psf wind term and the -39 psf net demand describe different quantities. Mark which one the submittal reports, and retain the calculation and assembly approval's resistance basis.
Does ASCE 7-22 require tornado design?
Chapter 32 adds a separate tornado load check. The FEMA/NIST guide's minimum-requirement screen addresses Risk Category III and IV structures in the mapped tornado-prone region. It checks both a tornado speed of at least 60 mph and an exposure-dependent comparison with basic wind speed V. The comparisons are Vt at least 0.5V for Exposure B, 0.6V for Exposure C and 0.67V for Exposure D. An owner can specify tornado design even when that minimum-requirement screen does not require it.
At V = 120 mph in Exposure C, the comparison speed is 72 mph. A Vt of 70 mph passes the 60 mph screen but fails the exposure comparison; 72 mph meets both speed thresholds. Record that result with the risk category and location screen. An owner's separate tornado-design requirement still applies.
FEMA/NIST defines the effective plan area for an essential facility using the smallest convex polygon enclosing the facility and structures needed to keep it operating. A hospital's supporting central utility plant belongs in that area even when it is structurally separate. Using only the hospital roof footprint can select the wrong tornado speed. Save the area sketch with the hazard report.
What to retain from the ASCE Hazard Tool
ASCE's Hazard Tool instructions require selection of the standard edition, risk category and, for seismic data, site soil class. Its full-report function assembles the location's hazard results in a PDF. Save that report with the structural criteria and identify the inputs used; a screenshot containing only a wind speed loses the design context.
Use the report as the hazard-data record feeding the calculations. Keep the resulting load schedules with the structural QA package so an inspector can trace a substituted component back to the same design basis.
Distinctions
- ASCE 7 commentary
- Commentary explains the provisions and their background. Identify whether a cited passage belongs to the standard's requirements or the accompanying explanation.
Frequently asked questions
Does ASCE 7 tornado design make a building a storm shelter?
The FEMA/NIST guide distinguishes conventional Chapter 32 design from storm shelter and safe-room design. ICC's current published shelter standard is ANSI/ICC 500-2023, which also addresses occupant needs such as egress and ventilation. Ordinary tornado load calculations do not establish shelter qualification.
Sources checked
- ASCE: current ASCE/SEI 7 edition, supplements and errata registry
- ASCE: ASCE/SEI 7-22 scope and official access options
- FEMA/NIST: Design Guide for New Tornado Load Requirements in ASCE 7-22, January 2023, pages 1, 5, 6, 8 and 15
- ASCE: Hazard Tool inputs and report instructions
- Carlisle SynTec: Adjustments Between ASCE 7-16 and ASCE 7-22, March 12, 2025
- ICC: ANSI/ICC 500-2023, current published storm-shelter standard and occupant safety scope
Also defined as
- Datacenter: The loads standard, including seismic and wind, with nonstructural component anchorage in Chapter 13 and the Ip importance factor