ANVILFIELD Try FieldOS

Field glossary · property

CSP

CSP, concrete surface profile, is assigned by matching prepared concrete to ICRI texture comparators: a CSP 4 record identifies a class rather than a 4-mil depth. Specify the required comparator and the areas it applies to. Where profile depth also matters, measure and report it separately, retaining a labeled replica when later review of the concealed texture is needed.

Concrete surface profile, the ICRI roughness scale for a prepared bonding surface, higher numbers rougher

Used across 3 Anvilfield field guides, most in Concrete.
Updated

Why CSP numbers do not convert directly to mils

ICRI Guideline 310.2R-2013 includes CSP 10, the additional aggressive profile introduced for concrete repair. Older references that stop at CSP 9 omit that profile. The comparators represent different prepared textures; they are not ten equal steps on a depth ruler.

A CSP 4 requirement therefore does not mean a 4-mil surface or a texture twice as deep as CSP 2. Record the comparator result as a CSP class. Where a specification also requires a measured depth, record that result separately with its instrument and units. Peaks, valleys, and the spacing of features all affect how a texture compares.

Keep a profile record after the coating hides it

ASTM D7682-17(2022) describes making a permanent concrete-surface replica with putty for comparison with visual standards or measurement of profile depth. A labeled replica preserves more evidence than a photograph taken under an unknown light angle.

Index each replica to a floor plan or repair location and identify the prepared area it represents. A single favorable patch at the equipment setup point does not document a doorway, wall edge, or hand-ground penetration surround. Those areas often receive different preparation equipment and deserve separate records.

ASTM D8271-26 is the current method for measuring profile depth directly on prepared concrete. Its depth result and a D7682 replica answer different documentation needs: the direct reading quantifies the surface, while the retained replica lets another inspector revisit its texture after coating. Specify the method alongside the required CSP class.

Resolve a roughness dispute before primer

A floor specification calls for CSP 4. The main shot-blasted field compares with that reference, but a hand-ground perimeter compares with CSP 2. Treat the perimeter as a separate preparation area and correct its texture before accepting the whole floor. Averaging the two CSP numbers would invent a measurement the comparator system does not provide.

Preserve the profile record at the resinous-flooring handoff and after preparing a concrete repair cavity. Pair it with separate cleanliness and moisture results so later adhesion failures can be compared with the substrate actually accepted.

Distinctions

Surface cleanliness
A retained profile replica documents the concrete's geometry. It supplies no acceptance result for oil contamination or residual dust, which need their own inspection evidence.
Dry film thickness
Dry film thickness measures the cured coating. Surface-profile depth measures the concrete beneath it.

Frequently asked questions

Is CSP 10 a real ICRI profile?

Yes. ICRI added it in the 2013 guideline revision for more aggressive concrete repair preparation.

Can I specify CSP using only a micrometer number?

Specify the required texture class explicitly when the system calls for CSP. A numerical depth supplements that requirement; it is not an automatic conversion to a comparator class.

Sources checked

Also defined as

  • Concrete surface profile, the ICRI roughness scale from CSP 1 (smooth) to CSP 9 to 10 (coarse)
  • Concrete surface profile, the ICRI 1 to 10 roughness scale that grades the prepared slab

Where this shows up

Next step: Browse floor coating bids

Back to the full field glossary